Page 38 - Produits Bourns Inc. - Tubes à éclateur à gaz (GDT) | Heisener Electronics
Contactez nous
SalesDept@heisener.com +86-755-83210559 ext. 809
Language Translation

* Please refer to the English Version as our Official Version.

Produits Bourns Inc. - Tubes à éclateur à gaz (GDT)

Dossiers 1 289
Page  38/43
Image
Référence
Fabricant
Description
paquet
Stock
Quantité
Impulse Discharge Current (8/20µs)
Tolerance
Number of Poles
Fail Short
Mounting Type
Package / Case
2097-140-DLF
Bourns Inc.

GDT 1400V 20% 20KA THROUGH HOLE

  • Voltage - DC Spark Over (Nom): 1400V
  • Impulse Discharge Current (8/20µs): 20000A (20kA)
  • Tolerance: ±20%
  • Number of Poles: 2
  • Fail Short: No
  • Mounting Type: Through Hole
  • Package / Case: Axial Cylinder
paquet: Axial Cylinder
Stock2 016
20000A (20kA)
±20%
2
No
Through Hole
Axial Cylinder
2097-120-DLF
Bourns Inc.

GDT 1200V 20% 20KA THROUGH HOLE

  • Voltage - DC Spark Over (Nom): 1200V
  • Impulse Discharge Current (8/20µs): 20000A (20kA)
  • Tolerance: ±20%
  • Number of Poles: 2
  • Fail Short: No
  • Mounting Type: Through Hole
  • Package / Case: Axial Cylinder
paquet: Axial Cylinder
Stock6 606
20000A (20kA)
±20%
2
No
Through Hole
Axial Cylinder
2063-80-ALF
Bourns Inc.

GDT 800V 20% 60KA

  • Voltage - DC Spark Over (Nom): 800V
  • Impulse Discharge Current (8/20µs): 60000A (60kA)
  • Tolerance: ±20%
  • Number of Poles: 2
  • Fail Short: No
  • Mounting Type: User Defined
  • Package / Case: Cylinder No Lead
paquet: Cylinder No Lead
Stock6 516
60000A (60kA)
±20%
2
No
User Defined
Cylinder No Lead
2063-60-ALF
Bourns Inc.

GDT 600V 20% 60KA

  • Voltage - DC Spark Over (Nom): 600V
  • Impulse Discharge Current (8/20µs): 60000A (60kA)
  • Tolerance: ±20%
  • Number of Poles: 2
  • Fail Short: No
  • Mounting Type: User Defined
  • Package / Case: Cylinder No Lead
paquet: Cylinder No Lead
Stock2 988
60000A (60kA)
±20%
2
No
User Defined
Cylinder No Lead
2063-47-ALF
Bourns Inc.

GDT 470V 20% 60KA

  • Voltage - DC Spark Over (Nom): 470V
  • Impulse Discharge Current (8/20µs): 60000A (60kA)
  • Tolerance: ±20%
  • Number of Poles: 2
  • Fail Short: No
  • Mounting Type: User Defined
  • Package / Case: Cylinder No Lead
paquet: Cylinder No Lead
Stock7 416
60000A (60kA)
±20%
2
No
User Defined
Cylinder No Lead
2063-35-ALF
Bourns Inc.

GDT 350V 20% 60KA

  • Voltage - DC Spark Over (Nom): 350V
  • Impulse Discharge Current (8/20µs): 60000A (60kA)
  • Tolerance: ±20%
  • Number of Poles: 2
  • Fail Short: No
  • Mounting Type: User Defined
  • Package / Case: Cylinder No Lead
paquet: Cylinder No Lead
Stock3 780
60000A (60kA)
±20%
2
No
User Defined
Cylinder No Lead
2063-23-ALF
Bourns Inc.

GDT 230V 20% 60KA

  • Voltage - DC Spark Over (Nom): 230V
  • Impulse Discharge Current (8/20µs): 60000A (60kA)
  • Tolerance: ±20%
  • Number of Poles: 2
  • Fail Short: No
  • Mounting Type: User Defined
  • Package / Case: Cylinder No Lead
paquet: Cylinder No Lead
Stock3 312
60000A (60kA)
±20%
2
No
User Defined
Cylinder No Lead
2063-70-ALF
Bourns Inc.

GDT 700V 20% 60KA

  • Voltage - DC Spark Over (Nom): 700V
  • Impulse Discharge Current (8/20µs): 60000A (60kA)
  • Tolerance: ±20%
  • Number of Poles: 2
  • Fail Short: No
  • Mounting Type: User Defined
  • Package / Case: Cylinder No Lead
paquet: Cylinder No Lead
Stock2 232
60000A (60kA)
±20%
2
No
User Defined
Cylinder No Lead
2063-42-ALF
Bourns Inc.

GDT 420V 20% 60KA

  • Voltage - DC Spark Over (Nom): 420V
  • Impulse Discharge Current (8/20µs): 60000A (60kA)
  • Tolerance: ±20%
  • Number of Poles: 2
  • Fail Short: No
  • Mounting Type: User Defined
  • Package / Case: Cylinder No Lead
paquet: Cylinder No Lead
Stock2 628
60000A (60kA)
±20%
2
No
User Defined
Cylinder No Lead
2063-25-ALF
Bourns Inc.

GDT 250V 20% 60KA

  • Voltage - DC Spark Over (Nom): 250V
  • Impulse Discharge Current (8/20µs): 60000A (60kA)
  • Tolerance: ±20%
  • Number of Poles: 2
  • Fail Short: No
  • Mounting Type: User Defined
  • Package / Case: Cylinder No Lead
paquet: Cylinder No Lead
Stock5 670
60000A (60kA)
±20%
2
No
User Defined
Cylinder No Lead
2061-60-ALF
Bourns Inc.

GDT 600V 20% 40KA

  • Voltage - DC Spark Over (Nom): 600V
  • Impulse Discharge Current (8/20µs): 40000A (40kA)
  • Tolerance: ±20%
  • Number of Poles: 2
  • Fail Short: No
  • Mounting Type: User Defined
  • Package / Case: Cylinder No Lead
paquet: Cylinder No Lead
Stock4 482
40000A (40kA)
±20%
2
No
User Defined
Cylinder No Lead
2061-47-ALF
Bourns Inc.

GDT 470V 20% 40KA

  • Voltage - DC Spark Over (Nom): 470V
  • Impulse Discharge Current (8/20µs): 40000A (40kA)
  • Tolerance: ±20%
  • Number of Poles: 2
  • Fail Short: No
  • Mounting Type: User Defined
  • Package / Case: Cylinder No Lead
paquet: Cylinder No Lead
Stock7 830
40000A (40kA)
±20%
2
No
User Defined
Cylinder No Lead
2061-42-ALF
Bourns Inc.

GDT 420V 20% 40KA

  • Voltage - DC Spark Over (Nom): 420V
  • Impulse Discharge Current (8/20µs): 40000A (40kA)
  • Tolerance: ±20%
  • Number of Poles: 2
  • Fail Short: No
  • Mounting Type: User Defined
  • Package / Case: Cylinder No Lead
paquet: Cylinder No Lead
Stock5 220
40000A (40kA)
±20%
2
No
User Defined
Cylinder No Lead
2061-35-ALF
Bourns Inc.

GDT 350V 20% 40KA

  • Voltage - DC Spark Over (Nom): 350V
  • Impulse Discharge Current (8/20µs): 40000A (40kA)
  • Tolerance: ±20%
  • Number of Poles: 2
  • Fail Short: No
  • Mounting Type: User Defined
  • Package / Case: Cylinder No Lead
paquet: Cylinder No Lead
Stock5 724
40000A (40kA)
±20%
2
No
User Defined
Cylinder No Lead
2061-23-ALF
Bourns Inc.

GDT 230V 20% 40KA

  • Voltage - DC Spark Over (Nom): 230V
  • Impulse Discharge Current (8/20µs): 40000A (40kA)
  • Tolerance: ±20%
  • Number of Poles: 2
  • Fail Short: No
  • Mounting Type: User Defined
  • Package / Case: Cylinder No Lead
paquet: Cylinder No Lead
Stock7 830
40000A (40kA)
±20%
2
No
User Defined
Cylinder No Lead
2061-80-ALF
Bourns Inc.

GDT 800V 20% 40KA

  • Voltage - DC Spark Over (Nom): 800V
  • Impulse Discharge Current (8/20µs): 40000A (40kA)
  • Tolerance: ±20%
  • Number of Poles: 2
  • Fail Short: No
  • Mounting Type: User Defined
  • Package / Case: Cylinder No Lead
paquet: Cylinder No Lead
Stock3 834
40000A (40kA)
±20%
2
No
User Defined
Cylinder No Lead
2061-70-ALF
Bourns Inc.

GDT 700V 20% 40KA

  • Voltage - DC Spark Over (Nom): 700V
  • Impulse Discharge Current (8/20µs): 40000A (40kA)
  • Tolerance: ±20%
  • Number of Poles: 2
  • Fail Short: No
  • Mounting Type: User Defined
  • Package / Case: Cylinder No Lead
paquet: Cylinder No Lead
Stock4 950
40000A (40kA)
±20%
2
No
User Defined
Cylinder No Lead
2061-30-ALF
Bourns Inc.

GDT 300V 20% 40KA

  • Voltage - DC Spark Over (Nom): 300V
  • Impulse Discharge Current (8/20µs): 40000A (40kA)
  • Tolerance: ±20%
  • Number of Poles: 2
  • Fail Short: No
  • Mounting Type: User Defined
  • Package / Case: Cylinder No Lead
paquet: Cylinder No Lead
Stock7 704
40000A (40kA)
±20%
2
No
User Defined
Cylinder No Lead
2061-25-ALF
Bourns Inc.

GDT 250V 20% 40KA

  • Voltage - DC Spark Over (Nom): 250V
  • Impulse Discharge Current (8/20µs): 40000A (40kA)
  • Tolerance: ±20%
  • Number of Poles: 2
  • Fail Short: No
  • Mounting Type: User Defined
  • Package / Case: Cylinder No Lead
paquet: Cylinder No Lead
Stock2 178
40000A (40kA)
±20%
2
No
User Defined
Cylinder No Lead
2047-35-BNI
Bourns Inc.

GDT 350V 20% 40KA THROUGH HOLE

  • Voltage - DC Spark Over (Nom): 350V
  • Impulse Discharge Current (8/20µs): 40000A (40kA)
  • Tolerance: ±20%
  • Number of Poles: 2
  • Fail Short: No
  • Mounting Type: Through Hole
  • Package / Case: Axial Cylinder, Radial Bend
paquet: Axial Cylinder, Radial Bend
Stock7 398
40000A (40kA)
±20%
2
No
Through Hole
Axial Cylinder, Radial Bend
2047-35-BLF
Bourns Inc.

GDT 350V 20% 40KA THROUGH HOLE

  • Voltage - DC Spark Over (Nom): 350V
  • Impulse Discharge Current (8/20µs): 40000A (40kA)
  • Tolerance: ±20%
  • Number of Poles: 2
  • Fail Short: No
  • Mounting Type: Through Hole
  • Package / Case: Axial Cylinder, Radial Bend
paquet: Axial Cylinder, Radial Bend
Stock7 182
40000A (40kA)
±20%
2
No
Through Hole
Axial Cylinder, Radial Bend
2047-23-BNI
Bourns Inc.

GDT 230V 20% 40KA THROUGH HOLE

  • Voltage - DC Spark Over (Nom): 230V
  • Impulse Discharge Current (8/20µs): 40000A (40kA)
  • Tolerance: ±20%
  • Number of Poles: 2
  • Fail Short: No
  • Mounting Type: Through Hole
  • Package / Case: Axial Cylinder, Radial Bend
paquet: Axial Cylinder, Radial Bend
Stock5 454
40000A (40kA)
±20%
2
No
Through Hole
Axial Cylinder, Radial Bend
2047-23-BLF
Bourns Inc.

GDT 230V 20% 40KA THROUGH HOLE

  • Voltage - DC Spark Over (Nom): 230V
  • Impulse Discharge Current (8/20µs): 40000A (40kA)
  • Tolerance: ±20%
  • Number of Poles: 2
  • Fail Short: No
  • Mounting Type: Through Hole
  • Package / Case: Axial Cylinder, Radial Bend
paquet: Axial Cylinder, Radial Bend
Stock7 560
40000A (40kA)
±20%
2
No
Through Hole
Axial Cylinder, Radial Bend
2047-15-BNI
Bourns Inc.

GDT 150V 20% 40KA THROUGH HOLE

  • Voltage - DC Spark Over (Nom): 150V
  • Impulse Discharge Current (8/20µs): 40000A (40kA)
  • Tolerance: ±20%
  • Number of Poles: 2
  • Fail Short: No
  • Mounting Type: Through Hole
  • Package / Case: Axial Cylinder, Radial Bend
paquet: Axial Cylinder, Radial Bend
Stock5 778
40000A (40kA)
±20%
2
No
Through Hole
Axial Cylinder, Radial Bend
2047-15-BLF
Bourns Inc.

GDT 150V 20% 40KA THROUGH HOLE

  • Voltage - DC Spark Over (Nom): 150V
  • Impulse Discharge Current (8/20µs): 40000A (40kA)
  • Tolerance: ±20%
  • Number of Poles: 2
  • Fail Short: No
  • Mounting Type: Through Hole
  • Package / Case: Axial Cylinder, Radial Bend
paquet: Axial Cylinder, Radial Bend
Stock8 964
40000A (40kA)
±20%
2
No
Through Hole
Axial Cylinder, Radial Bend
2047-09-BNI
Bourns Inc.

GDT 90V 20% 40KA THROUGH HOLE

  • Voltage - DC Spark Over (Nom): 90V
  • Impulse Discharge Current (8/20µs): 40000A (40kA)
  • Tolerance: ±20%
  • Number of Poles: 2
  • Fail Short: No
  • Mounting Type: Through Hole
  • Package / Case: Axial Cylinder, Radial Bend
paquet: Axial Cylinder, Radial Bend
Stock7 578
40000A (40kA)
±20%
2
No
Through Hole
Axial Cylinder, Radial Bend
2047-09-BLF
Bourns Inc.

GDT 90V 20% 40KA THROUGH HOLE

  • Voltage - DC Spark Over (Nom): 90V
  • Impulse Discharge Current (8/20µs): 40000A (40kA)
  • Tolerance: ±20%
  • Number of Poles: 2
  • Fail Short: No
  • Mounting Type: Through Hole
  • Package / Case: Axial Cylinder, Radial Bend
paquet: Axial Cylinder, Radial Bend
Stock5 004
40000A (40kA)
±20%
2
No
Through Hole
Axial Cylinder, Radial Bend
2047-35-ANI
Bourns Inc.

GDT 350V 20% 40KA

  • Voltage - DC Spark Over (Nom): 350V
  • Impulse Discharge Current (8/20µs): 40000A (40kA)
  • Tolerance: ±20%
  • Number of Poles: 2
  • Fail Short: No
  • Mounting Type: User Defined
  • Package / Case: Cylinder No Lead
paquet: Cylinder No Lead
Stock5 940
40000A (40kA)
±20%
2
No
User Defined
Cylinder No Lead
2047-23-ANI
Bourns Inc.

GDT 230V 20% 40KA

  • Voltage - DC Spark Over (Nom): 230V
  • Impulse Discharge Current (8/20µs): 40000A (40kA)
  • Tolerance: ±20%
  • Number of Poles: 2
  • Fail Short: No
  • Mounting Type: User Defined
  • Package / Case: Cylinder No Lead
paquet: Cylinder No Lead
Stock3 744
40000A (40kA)
±20%
2
No
User Defined
Cylinder No Lead
2047-15-ANI
Bourns Inc.

GDT 150V 20% 40KA

  • Voltage - DC Spark Over (Nom): 150V
  • Impulse Discharge Current (8/20µs): 40000A (40kA)
  • Tolerance: ±20%
  • Number of Poles: 2
  • Fail Short: No
  • Mounting Type: User Defined
  • Package / Case: Cylinder No Lead
paquet: Cylinder No Lead
Stock3 546
40000A (40kA)
±20%
2
No
User Defined
Cylinder No Lead