Page 2 - Produits Bourns Inc. - Tubes à éclateur à gaz (GDT) | Heisener Electronics
Contactez nous
SalesDept@heisener.com +86-755-83210559 ext. 815
Language Translation

* Please refer to the English Version as our Official Version.

Produits Bourns Inc. - Tubes à éclateur à gaz (GDT)

Dossiers 1 289
Page  2/43
Image
Référence
Fabricant
Description
paquet
Stock
Quantité
Impulse Discharge Current (8/20µs)
Tolerance
Number of Poles
Fail Short
Mounting Type
Package / Case
2056-23-B2LF
Bourns Inc.

GDT 230V 20% 5KA THROUGH HOLE

  • Voltage - DC Spark Over (Nom): 230V
  • Impulse Discharge Current (8/20µs): 5000A (5kA)
  • Tolerance: ±20%
  • Number of Poles: 3
  • Fail Short: No
  • Mounting Type: Through Hole
  • Package / Case: Axial Cylinder, 3 Lead (Radial Bend)
paquet: Axial Cylinder, 3 Lead (Radial Bend)
Stock17 730
5000A (5kA)
±20%
3
No
Through Hole
Axial Cylinder, 3 Lead (Radial Bend)
2051-42-SM-RPLF
Bourns Inc.

GDT 420V 25% 2KA SURFACE MOUNT

  • Voltage - DC Spark Over (Nom): 420V
  • Impulse Discharge Current (8/20µs): 2000A (2kA)
  • Tolerance: ±25%
  • Number of Poles: 2
  • Fail Short: No
  • Mounting Type: Surface Mount
  • Package / Case: 1812 (4532 Metric)
paquet: 1812 (4532 Metric)
Stock19 248
2000A (2kA)
±25%
2
No
Surface Mount
1812 (4532 Metric)
2026-35-C2LF
Bourns Inc.

GDT 350V 20% 20KA THROUGH HOLE

  • Voltage - DC Spark Over (Nom): 350V
  • Impulse Discharge Current (8/20µs): 20000A (20kA)
  • Tolerance: ±20%
  • Number of Poles: 3
  • Fail Short: No
  • Mounting Type: Through Hole
  • Package / Case: Axial Cylinder, 3 Lead (Radial Bend)
paquet: Axial Cylinder, 3 Lead (Radial Bend)
Stock19 236
20000A (20kA)
±20%
3
No
Through Hole
Axial Cylinder, 3 Lead (Radial Bend)
2026-15-C2
Bourns Inc.

GDT 150V 20% 20KA THROUGH HOLE

  • Voltage - DC Spark Over (Nom): 150V
  • Impulse Discharge Current (8/20µs): 20000A (20kA)
  • Tolerance: ±20%
  • Number of Poles: 3
  • Fail Short: No
  • Mounting Type: Through Hole
  • Package / Case: Axial Cylinder, 3 Lead (Radial Bend)
paquet: Axial Cylinder, 3 Lead (Radial Bend)
Stock28 002
20000A (20kA)
±20%
3
No
Through Hole
Axial Cylinder, 3 Lead (Radial Bend)
SA2-7200-CLT-STD
Bourns Inc.

GDT 7200V 20% 5KA THROUGH HOLE

  • Voltage - DC Spark Over (Nom): 7200V
  • Impulse Discharge Current (8/20µs): 5000A (5kA)
  • Tolerance: ±20%
  • Number of Poles: 2
  • Fail Short: No
  • Mounting Type: Through Hole
  • Package / Case: Axial Cylinder
paquet: Axial Cylinder
Stock52 128
5000A (5kA)
±20%
2
No
Through Hole
Axial Cylinder
2095-350-BLF
Bourns Inc.

GDT 3500V 20% 5KA THROUGH HOLE

  • Voltage - DC Spark Over (Nom): 3500V
  • Impulse Discharge Current (8/20µs): 5000A (5kA)
  • Tolerance: ±20%
  • Number of Poles: 2
  • Fail Short: No
  • Mounting Type: Through Hole
  • Package / Case: Axial Cylinder
paquet: Axial Cylinder
Stock14 874
5000A (5kA)
±20%
2
No
Through Hole
Axial Cylinder
2027-15-BLF
Bourns Inc.

GDT 150V 15% 10KA THROUGH HOLE

  • Voltage - DC Spark Over (Nom): 150V
  • Impulse Discharge Current (8/20µs): 10000A (10kA)
  • Tolerance: ±15%
  • Number of Poles: 2
  • Fail Short: No
  • Mounting Type: Through Hole
  • Package / Case: Axial Cylinder
paquet: Axial Cylinder
Stock12 228
10000A (10kA)
±15%
2
No
Through Hole
Axial Cylinder
2027-09-BLF
Bourns Inc.

GDT 90V 20% 10KA THROUGH HOLE

  • Voltage - DC Spark Over (Nom): 90V
  • Impulse Discharge Current (8/20µs): 10000A (10kA)
  • Tolerance: ±20%
  • Number of Poles: 2
  • Fail Short: No
  • Mounting Type: Through Hole
  • Package / Case: Axial Cylinder
paquet: Axial Cylinder
Stock23 472
10000A (10kA)
±20%
2
No
Through Hole
Axial Cylinder
2037-09-BLF
Bourns Inc.

GDT 90V 20% 5KA THROUGH HOLE

  • Voltage - DC Spark Over (Nom): 90V
  • Impulse Discharge Current (8/20µs): 5000A (5kA)
  • Tolerance: ±20%
  • Number of Poles: 2
  • Fail Short: No
  • Mounting Type: Through Hole
  • Package / Case: Axial Cylinder
paquet: Axial Cylinder
Stock18 366
5000A (5kA)
±20%
2
No
Through Hole
Axial Cylinder
2038-110-SM-RPLF
Bourns Inc.

GDT 1100V 25% 5KA SURFACE MOUNT

  • Voltage - DC Spark Over (Nom): 1100V
  • Impulse Discharge Current (8/20µs): 5000A (5kA)
  • Tolerance: ±25%
  • Number of Poles: 3
  • Fail Short: No
  • Mounting Type: Surface Mount
  • Package / Case: 3-SMD Cylinder Square End
paquet: 3-SMD Cylinder Square End
Stock26 184
5000A (5kA)
±25%
3
No
Surface Mount
3-SMD Cylinder Square End
2035-09-SM
Bourns Inc.

GDT 90V 20% 5KA SURFACE MOUNT

  • Voltage - DC Spark Over (Nom): 90V
  • Impulse Discharge Current (8/20µs): 5000A (5kA)
  • Tolerance: ±20%
  • Number of Poles: 2
  • Fail Short: No
  • Mounting Type: Surface Mount
  • Package / Case: 2-SMD Cylinder Square End
paquet: 2-SMD Cylinder Square End
Stock15 306
5000A (5kA)
±20%
2
No
Surface Mount
2-SMD Cylinder Square End
2054-23-SM-RPLF
Bourns Inc.

GDT 230V 20% 5KA SURFACE MOUNT

  • Voltage - DC Spark Over (Nom): 230V
  • Impulse Discharge Current (8/20µs): 5000A (5kA)
  • Tolerance: ±20%
  • Number of Poles: 3
  • Fail Short: No
  • Mounting Type: Surface Mount
  • Package / Case: 3-SMD Cylinder Square End
paquet: 3-SMD Cylinder Square End
Stock32 700
5000A (5kA)
±20%
3
No
Surface Mount
3-SMD Cylinder Square End
2049-60-BLF
Bourns Inc.

GDT 600V 30% 15KA THROUGH HOLE

  • Voltage - DC Spark Over (Nom): 600V
  • Impulse Discharge Current (8/20µs): 15000A (15kA)
  • Tolerance: ±30%
  • Number of Poles: 2
  • Fail Short: No
  • Mounting Type: Through Hole
  • Package / Case: Axial Cylinder
paquet: Axial Cylinder
Stock18 072
15000A (15kA)
±30%
2
No
Through Hole
Axial Cylinder
2057-47-BLF
Bourns Inc.

GDT 470V 20% 5KA THROUGH HOLE

  • Voltage - DC Spark Over (Nom): 470V
  • Impulse Discharge Current (8/20µs): 5000A (5kA)
  • Tolerance: ±20%
  • Number of Poles: 2
  • Fail Short: No
  • Mounting Type: Through Hole
  • Package / Case: Axial Cylinder
paquet: Axial Cylinder
Stock14 790
5000A (5kA)
±20%
2
No
Through Hole
Axial Cylinder
2093-270-SM-RPLF
Bourns Inc.

GDT 2700V 20% 3KA SURFACE MOUNT

  • Voltage - DC Spark Over (Nom): 2700V
  • Impulse Discharge Current (8/20µs): 3000A (3kA)
  • Tolerance: ±20%
  • Number of Poles: 2
  • Fail Short: No
  • Mounting Type: Surface Mount
  • Package / Case: 2-SMD Cylinder Square End
paquet: 2-SMD Cylinder Square End
Stock24 732
3000A (3kA)
±20%
2
No
Surface Mount
2-SMD Cylinder Square End
2031-42T-SM-RPLF
Bourns Inc.

GDT 360V 1KA SURFACE MOUNT

  • Voltage - DC Spark Over (Nom): 360V
  • Impulse Discharge Current (8/20µs): 1000A (1kA)
  • Tolerance: -
  • Number of Poles: 2
  • Fail Short: No
  • Mounting Type: Surface Mount
  • Package / Case: 2-SMD Cylinder Square End
paquet: 2-SMD Cylinder Square End
Stock14 436
1000A (1kA)
-
2
No
Surface Mount
2-SMD Cylinder Square End
2035-23-BT1LF
Bourns Inc.

GDT 230V 15% 5KA THROUGH HOLE

  • Voltage - DC Spark Over (Nom): 230V
  • Impulse Discharge Current (8/20µs): 5000A (5kA)
  • Tolerance: ±15%
  • Number of Poles: 2
  • Fail Short: No
  • Mounting Type: Through Hole
  • Package / Case: Axial Cylinder
paquet: Axial Cylinder
Stock28 716
5000A (5kA)
±15%
2
No
Through Hole
Axial Cylinder
2087-150-SM-RPLF
Bourns Inc.

GDT 1500V 20% 2KA SURFACE MOUNT

  • Voltage - DC Spark Over (Nom): 1500V
  • Impulse Discharge Current (8/20µs): 2000A (2kA)
  • Tolerance: ±20%
  • Number of Poles: 2
  • Fail Short: No
  • Mounting Type: Surface Mount
  • Package / Case: 2-SMD Cylinder Square End
paquet: 2-SMD Cylinder Square End
Stock26 160
2000A (2kA)
±20%
2
No
Surface Mount
2-SMD Cylinder Square End
hot 2035-35-SM-RPLF
Bourns Inc.

GDT 350V 15% 5KA SURFACE MOUNT

  • Voltage - DC Spark Over (Nom): 350V
  • Impulse Discharge Current (8/20µs): 5000A (5kA)
  • Tolerance: ±15%
  • Number of Poles: 2
  • Fail Short: No
  • Mounting Type: Surface Mount
  • Package / Case: 2-SMD Cylinder Square End
paquet: 2-SMD Cylinder Square End
Stock229 896
5000A (5kA)
±15%
2
No
Surface Mount
2-SMD Cylinder Square End
2053-09-SM-RPLF
Bourns Inc.

GDT 90V 20% 3KA SURFACE MOUNT

  • Voltage - DC Spark Over (Nom): 90V
  • Impulse Discharge Current (8/20µs): 3000A (3kA)
  • Tolerance: ±20%
  • Number of Poles: 2
  • Fail Short: No
  • Mounting Type: Surface Mount
  • Package / Case: 2-SMD Cylinder Square End
paquet: 2-SMD Cylinder Square End
Stock51 912
3000A (3kA)
±20%
2
No
Surface Mount
2-SMD Cylinder Square End
2051-23-SM-RPLF
Bourns Inc.

GDT 230V 25% 2KA SURFACE MOUNT

  • Voltage - DC Spark Over (Nom): 230V
  • Impulse Discharge Current (8/20µs): 2000A (2kA)
  • Tolerance: ±25%
  • Number of Poles: 2
  • Fail Short: No
  • Mounting Type: Surface Mount
  • Package / Case: 1812 (4532 Metric)
paquet: 1812 (4532 Metric)
Stock18 786
2000A (2kA)
±25%
2
No
Surface Mount
1812 (4532 Metric)
2051-40-SM-RPLF
Bourns Inc.

GDT 400V 25% 2KA SURFACE MOUNT

  • Voltage - DC Spark Over (Nom): 400V
  • Impulse Discharge Current (8/20µs): 2000A (2kA)
  • Tolerance: ±25%
  • Number of Poles: 2
  • Fail Short: No
  • Mounting Type: Surface Mount
  • Package / Case: 1812 (4532 Metric)
paquet: 1812 (4532 Metric)
Stock92 310
2000A (2kA)
±25%
2
No
Surface Mount
1812 (4532 Metric)
2026-07-C4
Bourns Inc.

GDT 75V 20% 20KA THROUGH HOLE

  • Voltage - DC Spark Over (Nom): 75V
  • Impulse Discharge Current (8/20µs): 20000A (20kA)
  • Tolerance: ±20%
  • Number of Poles: 3
  • Fail Short: No
  • Mounting Type: Through Hole
  • Package / Case: Axial Cylinder, 3 Lead (Radial Bend)
paquet: Axial Cylinder, 3 Lead (Radial Bend)
Stock14 460
20000A (20kA)
±20%
3
No
Through Hole
Axial Cylinder, 3 Lead (Radial Bend)
2026-09-C2LF
Bourns Inc.

GDT 90V 20% 20KA THROUGH HOLE

  • Voltage - DC Spark Over (Nom): 90V
  • Impulse Discharge Current (8/20µs): 20000A (20kA)
  • Tolerance: ±20%
  • Number of Poles: 3
  • Fail Short: No
  • Mounting Type: Through Hole
  • Package / Case: Axial Cylinder, 3 Lead (Radial Bend)
paquet: Axial Cylinder, 3 Lead (Radial Bend)
Stock19 140
20000A (20kA)
±20%
3
No
Through Hole
Axial Cylinder, 3 Lead (Radial Bend)
2036-09-SMLF
Bourns Inc.

GDT 90V 20% 10KA SURFACE MOUNT

  • Voltage - DC Spark Over (Nom): 90V
  • Impulse Discharge Current (8/20µs): 10000A (10kA)
  • Tolerance: ±20%
  • Number of Poles: 3
  • Fail Short: No
  • Mounting Type: Surface Mount
  • Package / Case: 3-SMD Cylinder Square End
paquet: 3-SMD Cylinder Square End
Stock16 038
10000A (10kA)
±20%
3
No
Surface Mount
3-SMD Cylinder Square End
2027-09-B
Bourns Inc.

GDT 90V 20% 10KA THROUGH HOLE

  • Voltage - DC Spark Over (Nom): 90V
  • Impulse Discharge Current (8/20µs): 10000A (10kA)
  • Tolerance: ±20%
  • Number of Poles: 2
  • Fail Short: No
  • Mounting Type: Through Hole
  • Package / Case: Axial Cylinder
paquet: Axial Cylinder
Stock21 954
10000A (10kA)
±20%
2
No
Through Hole
Axial Cylinder
2031-23T-SMLF
Bourns Inc.

GDT 185V 1KA SURFACE MOUNT

  • Voltage - DC Spark Over (Nom): 185V
  • Impulse Discharge Current (8/20µs): 1000A (1kA)
  • Tolerance: -
  • Number of Poles: 2
  • Fail Short: No
  • Mounting Type: Surface Mount
  • Package / Case: 2-SMD Cylinder Square End
paquet: 2-SMD Cylinder Square End
Stock19 608
1000A (1kA)
-
2
No
Surface Mount
2-SMD Cylinder Square End
2031-15T-SMLF
Bourns Inc.

GDT 60V 1KA SURFACE MOUNT

  • Voltage - DC Spark Over (Nom): 60V
  • Impulse Discharge Current (8/20µs): 1000A (1kA)
  • Tolerance: -
  • Number of Poles: 2
  • Fail Short: No
  • Mounting Type: Surface Mount
  • Package / Case: 2-SMD Cylinder Square End
paquet: 2-SMD Cylinder Square End
Stock16 512
1000A (1kA)
-
2
No
Surface Mount
2-SMD Cylinder Square End
2035-09-B5LF
Bourns Inc.

GDT 90V 20% 5KA THROUGH HOLE

  • Voltage - DC Spark Over (Nom): 90V
  • Impulse Discharge Current (8/20µs): 5000A (5kA)
  • Tolerance: ±20%
  • Number of Poles: 2
  • Fail Short: No
  • Mounting Type: Through Hole
  • Package / Case: Axial Cylinder
paquet: Axial Cylinder
Stock17 094
5000A (5kA)
±20%
2
No
Through Hole
Axial Cylinder
2035-23-BLF
Bourns Inc.

GDT 230V 15% 5KA THROUGH HOLE

  • Voltage - DC Spark Over (Nom): 230V
  • Impulse Discharge Current (8/20µs): 5000A (5kA)
  • Tolerance: ±15%
  • Number of Poles: 2
  • Fail Short: No
  • Mounting Type: Through Hole
  • Package / Case: Axial Cylinder
paquet: Axial Cylinder
Stock25 854
5000A (5kA)
±15%
2
No
Through Hole
Axial Cylinder