Page 4 - Produits Bourns Inc. - Tubes à éclateur à gaz (GDT) | Heisener Electronics
Contactez nous
SalesDept@heisener.com +86-755-83210559 ext. 803
Language Translation

* Please refer to the English Version as our Official Version.

Produits Bourns Inc. - Tubes à éclateur à gaz (GDT)

Dossiers 1 289
Page  4/43
Image
Référence
Fabricant
Description
paquet
Stock
Quantité
Impulse Discharge Current (8/20µs)
Tolerance
Number of Poles
Fail Short
Mounting Type
Package / Case
2045-47-BLF
Bourns Inc.

GDT 470V 30% 10KA THROUGH HOLE

  • Voltage - DC Spark Over (Nom): 470V
  • Impulse Discharge Current (8/20µs): 10000A (10kA)
  • Tolerance: ±30%
  • Number of Poles: 2
  • Fail Short: No
  • Mounting Type: Through Hole
  • Package / Case: Axial Cylinder
paquet: Axial Cylinder
Stock10 320
10000A (10kA)
±30%
2
No
Through Hole
Axial Cylinder
2026-07-C2
Bourns Inc.

GDT 75V 20% 20KA THROUGH HOLE

  • Voltage - DC Spark Over (Nom): 75V
  • Impulse Discharge Current (8/20µs): 20000A (20kA)
  • Tolerance: ±20%
  • Number of Poles: 3
  • Fail Short: No
  • Mounting Type: Through Hole
  • Package / Case: Axial Cylinder, 3 Lead (Radial Bend)
paquet: Axial Cylinder, 3 Lead (Radial Bend)
Stock8 712
20000A (20kA)
±20%
3
No
Through Hole
Axial Cylinder, 3 Lead (Radial Bend)
2036-07-B3LF
Bourns Inc.

GDT 75V 20% 10KA THROUGH HOLE

  • Voltage - DC Spark Over (Nom): 75V
  • Impulse Discharge Current (8/20µs): 10000A (10kA)
  • Tolerance: ±20%
  • Number of Poles: 3
  • Fail Short: No
  • Mounting Type: Through Hole
  • Package / Case: Axial Cylinder, 3 Lead (Radial Bend)
paquet: Axial Cylinder, 3 Lead (Radial Bend)
Stock18 456
10000A (10kA)
±20%
3
No
Through Hole
Axial Cylinder, 3 Lead (Radial Bend)
2027-23-BLF
Bourns Inc.

GDT 230V 15% 10KA THROUGH HOLE

  • Voltage - DC Spark Over (Nom): 230V
  • Impulse Discharge Current (8/20µs): 10000A (10kA)
  • Tolerance: ±15%
  • Number of Poles: 2
  • Fail Short: No
  • Mounting Type: Through Hole
  • Package / Case: Axial Cylinder
paquet: Axial Cylinder
Stock7 692
10000A (10kA)
±15%
2
No
Through Hole
Axial Cylinder
2027-47-B
Bourns Inc.

GDT 470V 15% 10KA THROUGH HOLE

  • Voltage - DC Spark Over (Nom): 470V
  • Impulse Discharge Current (8/20µs): 10000A (10kA)
  • Tolerance: ±15%
  • Number of Poles: 2
  • Fail Short: No
  • Mounting Type: Through Hole
  • Package / Case: Axial Cylinder
paquet: Axial Cylinder
Stock11 388
10000A (10kA)
±15%
2
No
Through Hole
Axial Cylinder
2095-250-BLF
Bourns Inc.

GDT 2500V 20% 5KA THROUGH HOLE

  • Voltage - DC Spark Over (Nom): 2500V
  • Impulse Discharge Current (8/20µs): 5000A (5kA)
  • Tolerance: ±20%
  • Number of Poles: 2
  • Fail Short: No
  • Mounting Type: Through Hole
  • Package / Case: Axial Cylinder
paquet: Axial Cylinder
Stock19 200
5000A (5kA)
±20%
2
No
Through Hole
Axial Cylinder
2027-25-BLF
Bourns Inc.

GDT 250V 15% 10KA THROUGH HOLE

  • Voltage - DC Spark Over (Nom): 250V
  • Impulse Discharge Current (8/20µs): 10000A (10kA)
  • Tolerance: ±15%
  • Number of Poles: 2
  • Fail Short: No
  • Mounting Type: Through Hole
  • Package / Case: Axial Cylinder
paquet: Axial Cylinder
Stock19 860
10000A (10kA)
±15%
2
No
Through Hole
Axial Cylinder
2027-35-BLF
Bourns Inc.

GDT 350V 15% 10KA THROUGH HOLE

  • Voltage - DC Spark Over (Nom): 350V
  • Impulse Discharge Current (8/20µs): 10000A (10kA)
  • Tolerance: ±15%
  • Number of Poles: 2
  • Fail Short: No
  • Mounting Type: Through Hole
  • Package / Case: Axial Cylinder
paquet: Axial Cylinder
Stock21 576
10000A (10kA)
±15%
2
No
Through Hole
Axial Cylinder
2027-07-SMLF
Bourns Inc.

GDT 75V 20% 10KA SURFACE MOUNT

  • Voltage - DC Spark Over (Nom): 75V
  • Impulse Discharge Current (8/20µs): 10000A (10kA)
  • Tolerance: ±20%
  • Number of Poles: 2
  • Fail Short: No
  • Mounting Type: Surface Mount
  • Package / Case: 2-SMD Cylinder Square End
paquet: 2-SMD Cylinder Square End
Stock6 120
10000A (10kA)
±20%
2
No
Surface Mount
2-SMD Cylinder Square End
2089-250-BLF
Bourns Inc.

GDT 2500V 20% 1.5KA THROUGH HOLE

  • Voltage - DC Spark Over (Nom): 2500V
  • Impulse Discharge Current (8/20µs): 1500A (1.5kA)
  • Tolerance: ±20%
  • Number of Poles: 2
  • Fail Short: No
  • Mounting Type: Through Hole
  • Package / Case: Axial Cylinder
paquet: Axial Cylinder
Stock9 384
1500A (1.5kA)
±20%
2
No
Through Hole
Axial Cylinder
2089-360-BLF
Bourns Inc.

GDT 3600V 20% 1.5KA THROUGH HOLE

  • Voltage - DC Spark Over (Nom): 3600V
  • Impulse Discharge Current (8/20µs): 1500A (1.5kA)
  • Tolerance: ±20%
  • Number of Poles: 2
  • Fail Short: No
  • Mounting Type: Through Hole
  • Package / Case: Axial Cylinder
paquet: Axial Cylinder
Stock20 544
1500A (1.5kA)
±20%
2
No
Through Hole
Axial Cylinder
2035-09-BLF
Bourns Inc.

GDT 90V 20% 5KA THROUGH HOLE

  • Voltage - DC Spark Over (Nom): 90V
  • Impulse Discharge Current (8/20µs): 5000A (5kA)
  • Tolerance: ±20%
  • Number of Poles: 2
  • Fail Short: No
  • Mounting Type: Through Hole
  • Package / Case: Axial Cylinder
paquet: Axial Cylinder
Stock12 480
5000A (5kA)
±20%
2
No
Through Hole
Axial Cylinder
2035-35-BLF
Bourns Inc.

GDT 350V 15% 5KA THROUGH HOLE

  • Voltage - DC Spark Over (Nom): 350V
  • Impulse Discharge Current (8/20µs): 5000A (5kA)
  • Tolerance: ±15%
  • Number of Poles: 2
  • Fail Short: No
  • Mounting Type: Through Hole
  • Package / Case: Axial Cylinder
paquet: Axial Cylinder
Stock22 380
5000A (5kA)
±15%
2
No
Through Hole
Axial Cylinder
2045-23-BLF
Bourns Inc.

GDT 230V 30% 10KA THROUGH HOLE

  • Voltage - DC Spark Over (Nom): 230V
  • Impulse Discharge Current (8/20µs): 10000A (10kA)
  • Tolerance: ±30%
  • Number of Poles: 2
  • Fail Short: No
  • Mounting Type: Through Hole
  • Package / Case: Axial Cylinder
paquet: Axial Cylinder
Stock22 080
10000A (10kA)
±30%
2
No
Through Hole
Axial Cylinder
2020-15T-C2LF
Bourns Inc.

GDT 60V 10KA THROUGH HOLE

  • Voltage - DC Spark Over (Nom): 60V
  • Impulse Discharge Current (8/20µs): 10000A (10kA)
  • Tolerance: -
  • Number of Poles: 3
  • Fail Short: No
  • Mounting Type: Through Hole
  • Package / Case: Axial Cylinder, 3 Lead (Radial Bend)
paquet: Axial Cylinder, 3 Lead (Radial Bend)
Stock11 652
10000A (10kA)
-
3
No
Through Hole
Axial Cylinder, 3 Lead (Radial Bend)
2026-25-C2LF
Bourns Inc.

GDT 250V 20% 20KA THROUGH HOLE

  • Voltage - DC Spark Over (Nom): 250V
  • Impulse Discharge Current (8/20µs): 20000A (20kA)
  • Tolerance: ±20%
  • Number of Poles: 3
  • Fail Short: No
  • Mounting Type: Through Hole
  • Package / Case: Axial Cylinder, 3 Lead (Radial Bend)
paquet: Axial Cylinder, 3 Lead (Radial Bend)
Stock14 580
20000A (20kA)
±20%
3
No
Through Hole
Axial Cylinder, 3 Lead (Radial Bend)
2027-60-BLF
Bourns Inc.

GDT 600V 15% 10KA THROUGH HOLE

  • Voltage - DC Spark Over (Nom): 600V
  • Impulse Discharge Current (8/20µs): 10000A (10kA)
  • Tolerance: ±15%
  • Number of Poles: 2
  • Fail Short: No
  • Mounting Type: Through Hole
  • Package / Case: Axial Cylinder
paquet: Axial Cylinder
Stock19 644
10000A (10kA)
±15%
2
No
Through Hole
Axial Cylinder
2027-47-BLF
Bourns Inc.

GDT 470V 15% 10KA THROUGH HOLE

  • Voltage - DC Spark Over (Nom): 470V
  • Impulse Discharge Current (8/20µs): 10000A (10kA)
  • Tolerance: ±15%
  • Number of Poles: 2
  • Fail Short: No
  • Mounting Type: Through Hole
  • Package / Case: Axial Cylinder
paquet: Axial Cylinder
Stock17 208
10000A (10kA)
±15%
2
No
Through Hole
Axial Cylinder
2036-60-B2LF
Bourns Inc.

GDT 600V 20% 10KA THROUGH HOLE

  • Voltage - DC Spark Over (Nom): 600V
  • Impulse Discharge Current (8/20µs): 10000A (10kA)
  • Tolerance: ±20%
  • Number of Poles: 3
  • Fail Short: No
  • Mounting Type: Through Hole
  • Package / Case: Axial Cylinder, 3 Lead (Radial Bend)
paquet: Axial Cylinder, 3 Lead (Radial Bend)
Stock8 658
10000A (10kA)
±20%
3
No
Through Hole
Axial Cylinder, 3 Lead (Radial Bend)
1820-28-A3
Bourns Inc.

GDT 28V 10KA DIN RAIL

  • Voltage - DC Spark Over (Nom): 28V
  • Impulse Discharge Current (8/20µs): 10000A (10kA)
  • Tolerance: -
  • Number of Poles: 3
  • Fail Short: No
  • Mounting Type: DIN Rail
  • Package / Case: Module, Plug-In Terminal Block
paquet: Module, Plug-In Terminal Block
Stock3 960
10000A (10kA)
-
3
No
DIN Rail
Module, Plug-In Terminal Block
SA2-5500-CLT-STD
Bourns Inc.

GDT 5500V 20% 5KA THROUGH HOLE

  • Voltage - DC Spark Over (Nom): 5500V
  • Impulse Discharge Current (8/20µs): 5000A (5kA)
  • Tolerance: ±20%
  • Number of Poles: 2
  • Fail Short: No
  • Mounting Type: Through Hole
  • Package / Case: Axial Cylinder
paquet: Axial Cylinder
Stock5 130
5000A (5kA)
±20%
2
No
Through Hole
Axial Cylinder
SA2-6200-CLT-STD
Bourns Inc.

GDT 6200V 20% 5KA THROUGH HOLE

  • Voltage - DC Spark Over (Nom): 6200V
  • Impulse Discharge Current (8/20µs): 5000A (5kA)
  • Tolerance: ±20%
  • Number of Poles: 2
  • Fail Short: No
  • Mounting Type: Through Hole
  • Package / Case: Axial Cylinder
paquet: Axial Cylinder
Stock4 482
5000A (5kA)
±20%
2
No
Through Hole
Axial Cylinder
SA2-6300-CLT-STD
Bourns Inc.

GDT 6300V 20% 5KA THROUGH HOLE

  • Voltage - DC Spark Over (Nom): 6300V
  • Impulse Discharge Current (8/20µs): 5000A (5kA)
  • Tolerance: ±20%
  • Number of Poles: 2
  • Fail Short: No
  • Mounting Type: Through Hole
  • Package / Case: Axial Cylinder
paquet: Axial Cylinder
Stock5 328
5000A (5kA)
±20%
2
No
Through Hole
Axial Cylinder
2030-42T-SM-RPLF
Bourns Inc.

GDT 360V 4KA SURFACE MOUNT

  • Voltage - DC Spark Over (Nom): 360V
  • Impulse Discharge Current (8/20µs): 4000A (4kA)
  • Tolerance: -
  • Number of Poles: 3
  • Fail Short: No
  • Mounting Type: Surface Mount
  • Package / Case: 3-SMD Cylinder Square End
paquet: 3-SMD Cylinder Square End
Stock14 058
4000A (4kA)
-
3
No
Surface Mount
3-SMD Cylinder Square End
hot 2038-35-SM-RPLF
Bourns Inc.

GDT 350V 25% 5KA SURFACE MOUNT

  • Voltage - DC Spark Over (Nom): 350V
  • Impulse Discharge Current (8/20µs): 5000A (5kA)
  • Tolerance: ±25%
  • Number of Poles: 3
  • Fail Short: No
  • Mounting Type: Surface Mount
  • Package / Case: 3-SMD Cylinder Square End
paquet: 3-SMD Cylinder Square End
Stock948 000
5000A (5kA)
±25%
3
No
Surface Mount
3-SMD Cylinder Square End
2036-60-SM-RPLF
Bourns Inc.

GDT 600V 20% 10KA SURFACE MOUNT

  • Voltage - DC Spark Over (Nom): 600V
  • Impulse Discharge Current (8/20µs): 10000A (10kA)
  • Tolerance: ±20%
  • Number of Poles: 3
  • Fail Short: No
  • Mounting Type: Surface Mount
  • Package / Case: 3-SMD Cylinder Square End
paquet: 3-SMD Cylinder Square End
Stock12 240
10000A (10kA)
±20%
3
No
Surface Mount
3-SMD Cylinder Square End
2036-09-BLF
Bourns Inc.

GDT 90V 20% 10KA THROUGH HOLE

  • Voltage - DC Spark Over (Nom): 90V
  • Impulse Discharge Current (8/20µs): 10000A (10kA)
  • Tolerance: ±20%
  • Number of Poles: 3
  • Fail Short: No
  • Mounting Type: Through Hole
  • Package / Case: Axial Cylinder, Radial Bend
paquet: Axial Cylinder, Radial Bend
Stock16 230
10000A (10kA)
±20%
3
No
Through Hole
Axial Cylinder, Radial Bend
2054-47-SM-RPLF
Bourns Inc.

GDT 470V 20% 5KA SURFACE MOUNT

  • Voltage - DC Spark Over (Nom): 470V
  • Impulse Discharge Current (8/20µs): 5000A (5kA)
  • Tolerance: ±20%
  • Number of Poles: 3
  • Fail Short: No
  • Mounting Type: Surface Mount
  • Package / Case: 3-SMD Cylinder Square End
paquet: 3-SMD Cylinder Square End
Stock5 166
5000A (5kA)
±20%
3
No
Surface Mount
3-SMD Cylinder Square End
2017-09-SMC-RPLF
Bourns Inc.

GDT 90V 10KA 20% SURFACE MOUNT

  • Voltage - DC Spark Over (Nom): 90V
  • Impulse Discharge Current (8/20µs): 10000A (10kA)
  • Tolerance: ±20%
  • Number of Poles: 2
  • Fail Short: No
  • Mounting Type: Surface Mount Vertical
  • Package / Case: 2-SMD
paquet: 2-SMD
Stock12 402
10000A (10kA)
±20%
2
No
Surface Mount Vertical
2-SMD
2031-15T-SM-RP3LF
Bourns Inc.

GDT 60V 1KA SURFACE MOUNT

  • Voltage - DC Spark Over (Nom): 60V
  • Impulse Discharge Current (8/20µs): 1000A (1kA)
  • Tolerance: -
  • Number of Poles: 2
  • Fail Short: No
  • Mounting Type: Surface Mount
  • Package / Case: 2-SMD Cylinder Square End
paquet: 2-SMD Cylinder Square End
Stock20 424
1000A (1kA)
-
2
No
Surface Mount
2-SMD Cylinder Square End